Keep water where it belongs.

Waterproofing and concrete repair for treatment plants, tanks, roofs and basements, delivered across India by people who build water infrastructure.

Book a Zexcrete site survey
Tanks to rooftops.One team for every wet structure on your site.
Survey before price.Cracks, joints and loads mapped before we quote.
Matched to the duty.Chemistry chosen for immersion, chemicals, sun or pressure.

One partner for every wet structure on your site

Leaks rarely respect contract boundaries. We treat the whole water path, from the effluent tank to the roof slab, with one survey and one accountable team.

1

Effluent and sewage treatment tanks

Linings that resist chemicals, abrasion and constant immersion.

2

Water treatment plants and reservoirs

Potable-grade linings for clear water tanks, filters and sumps.

3

Overhead and underground water tanks

Flexible coatings that seal walls, floors and construction joints.

4

Roofs, terraces and podiums

Seamless, UV-stable membranes for exposed slabs.

5

Basements and retaining walls

Treatment from inside or outside, against ground-water pressure.

6

Chemical bunds, pits and drains

Resin linings that contain spills and protect the concrete.

7

Wet areas and utility floors

Toilets, wash areas, kitchens, pump rooms and plant floors.

8

Joints, cracks and pipe entries

Sealing and injection where most leaks begin.

Most leaks start in four places

A coating fails for a reason. A repair that ignores the cause fails the same way again, so we diagnose before we specify.

01

Movement

Concrete expands, contracts and settles. Rigid coatings crack where the structure moves.

02

Water pressure

Tanks and basements push water through joints, honeycombs and tie-rod holes.

03

Chemical and sun attack

Effluent, chlorides and ultraviolet light break down unprotected concrete and resins.

04

Weak details

Joints, pipe entries, drains and parapet edges are where most leaks begin.

Specified for India's climates, not for a catalogue

Hot, dry plains

Large daily temperature swings. Membranes must stay flexible and reflect heat.

Humid coasts

Salt and moisture attack steel and resins. Concrete needs dense, protective linings.

Heavy monsoon belts

Long wet spells. Slopes, drains and seamless cover matter most.

Cold hill regions

Freezing and thawing open up cracks. Systems must bridge them and breathe.

The right chemistry depends on the duty

No single product suits a sunlit roof, a drinking-water tank and an effluent pit. We select the system for what the surface must survive.

SystemWhat it isBest used for
Crystalline treatmentCement-based slurry that grows crystals inside the concrete pores.Water tanks, basements, leaks from the negative side
Flexible cementitious membranePolymer-modified coating that moves with hairline cracks.Water tanks, wet areas, base coats on roofs
Chemical-resistant epoxy liningHard, dense resin lining with high chemical resistance.Effluent tanks, bunds, pits and drains
Polyurethane membraneElastic liquid membrane with a UV-stable finish.Roofs, terraces and podiums
Polyurea membraneThick sprayed elastomer that cures within minutes.Large roofs, tanks and containment areas
Injection resinsPolyurethane or epoxy resin injected into cracks and joints.Live leaks and structural cracks

Crystalline treatment

Cement-based slurry that grows crystals inside the concrete pores.

Best for: Water tanks, basements, leaks from the negative side

Flexible cementitious membrane

Polymer-modified coating that moves with hairline cracks.

Best for: Water tanks, wet areas, base coats on roofs

Chemical-resistant epoxy lining

Hard, dense resin lining with high chemical resistance.

Best for: Effluent tanks, bunds, pits and drains

Polyurethane membrane

Elastic liquid membrane with a UV-stable finish.

Best for: Roofs, terraces and podiums

Polyurea membrane

Thick sprayed elastomer that cures within minutes.

Best for: Large roofs, tanks and containment areas

Injection resins

Polyurethane or epoxy resin injected into cracks and joints.

Best for: Live leaks and structural cracks

Selection matrix

StructureCrystallineFlex. cement.EpoxyPU membranePolyureaInjection
Effluent and sewage tanks○●●○
Drinking-water tanks and plants●●○○
Roofs, terraces and podiums○●●
Basements and retaining walls●○●
Chemical bunds, pits and drains●●
Wet areas and utility floors●○○
Joints, cracks and pipe entries○●

● First choice   ○ Also used — Typical selection. The final system is fixed after the site survey.

Preparation decides how long it lasts

The membrane is the visible part of the job. Its life is set by the survey, the surface preparation and the repairs underneath.

1

Survey

Map cracks, joints, slopes and the water path.

2

Plan the shutdown

Agree draining, isolation and safe entry for tanks.

3

Strip

Remove failed coatings down to sound concrete.

4

Prepare

Grind or blast, clean and dry the surface.

5

Repair

Rebuild cracks, honeycombs and weak concrete.

6

Detail

Form fillets and seal joints and pipe entries.

7

Waterproof

Apply the chosen system to the full thickness.

8

Cure and protect

Cure fully before refilling or opening to traffic.

9

Hand over

Clear the site and inspect the work jointly.

Built by people who build water infrastructure

✓
Engineering-led.

An environmental engineering and EPC firm that designs and builds water and effluent treatment plants.

✓
Priced after a survey.

Quantities come from your structure, not from a guess.

✓
Chosen for the duty.

Systems selected for immersion, chemicals, pressure, heat, sun and your local climate.

✓
Safe in a working plant.

Permit-to-work, confined-space and work-at-height discipline.

✓
One all-inclusive rate.

A single rate per square foot, with extras stated up front.

Systems engineered for the duty, not picked from a catalogue

Every waterproofing failure we see started with a material that was wrong for the exposure. A crystalline slurry inside a chemical pit. A rigid epoxy on a moving joint. A cheap acrylic on a terrace that floods every monsoon. The coating did not fail — the selection did.

Cementitious crystalline technology

Cement-based slurry that reacts with moisture and free lime to grow insoluble crystals inside concrete pores and micro-cracks. Self-heals hairline cracks up to 0.4 mm. Becomes part of the concrete matrix — does not peel, blister or delaminate. Ideal for water-retaining structures, basements and negative-side waterproofing where coatings cannot be applied from the wet face.

Polymer-modified cementitious membranes

Two-component systems — a polymer dispersion mixed with a cementitious powder — that cure into a flexible, crack-bridging membrane. Withstand hairline structural movement while retaining strong adhesion to concrete, masonry and render. Applied by brush, roller or spray. Used on water tanks, wet areas, retaining walls, and as base coats under exposed roof membranes.

Chemical-resistant epoxy and vinyl ester linings

High-build resin linings engineered for continuous chemical immersion. Solvent-free, two-pack epoxy systems for general effluent and alkali exposure. Vinyl ester and novolac resins where acids, solvents or high temperatures exceed epoxy limits. Applied in multiple coats with glass-fibre reinforcement at joints and transitions. The standard for ETP tanks, acid bunds, chemical pits and industrial drains.

Liquid-applied polyurethane membranes

Single-component and two-component polyurethane membranes that cure into a seamless, UV-stable elastomeric film. High elongation handles thermal movement across roof slabs, terraces and podiums. Bonds directly to concrete without a primer on sound substrates. Aliphatic PU topcoats resist yellowing and chalking in direct sunlight. The go-to system for exposed roofs and terrace decks in India.

Spray-applied polyurea elastomers

Fast-cure, high-build elastomeric coatings applied by heated plural-component spray equipment. Gel time under 10 seconds. Builds 1.5–3.0 mm in a single pass. Extreme elongation (300–400%) and tensile strength. Resistant to abrasion, impact, chemicals and thermal cycling. Used on large roof areas, water and effluent tanks, containment bunds and structures where rapid return to service is critical.

Injection resins for active leaks

Polyurethane and acrylic injection resins pumped under pressure into cracks, construction joints, tie-rod holes and pipe penetrations. Hydrophilic PU foams expand on contact with water to seal active leaks within minutes. Rigid epoxy resins restore structural bond across dormant cracks. Microfine cement grouts fill wider voids and honeycombed concrete. The first line of treatment for live water ingress in basements and tanks.

How we select the system for your structure

Exposure analysis

What the surface must survive — constant immersion, chemical attack, UV, hydrostatic pressure, abrasion or thermal cycling.

Substrate assessment

Concrete condition, carbonation depth, moisture content, surface profile and reinforcement cover. Weak substrates need repair before any coating.

Movement and cracking

Structural movement, settlement, vibration and expected crack widths determine whether the system must be rigid, semi-flexible or fully elastic.

Service conditions

Potable water contact, food-grade compliance, temperature range, cleaning chemicals and mechanical traffic all narrow the choice.

We source from established Indian and international manufacturers with verified track records in industrial waterproofing. The specific manufacturer and product system is named in your quotation after the site survey.

Book a Zexcrete site survey

Zexcrete is the waterproofing and concrete repair service of Zexcorp Services Private Limited. Serving clients across India.

Your information is kept confidential and used only for this enquiry.

Book a survey